The F550CMOS1-D4A is a computerized optical collimator system developed for indoor inspection and calibration of surveying instruments. Combining an optical collimator assembly, a precision mechanical platform, CMOS digital imaging and dedicated calibration software, it provides a computer-assisted approach to instrument error measurement.
Unlike conventional optical calibration stands and analog CCD observation systems, the F550CMOS1-D4A integrates digital image acquisition with specialized measurement software. It is intended for professional facilities requiring quantitative analysis of surveying instrument alignment errors.
The F550CMOS1-D4A is designed to support the inspection of optical and mechanical axis relationships in surveying instruments.
Its dedicated calibration software supports the measurement of several important instrument errors.
Collimation error is associated with the relationship between the telescope's line of sight and the horizontal rotation axis. Measuring this error is an important part of total station and theodolite inspection.
Vertical index error affects the reference used for vertical angle measurements. The computerized calibration system supports relevant measurements during instrument inspection and adjustment.
The inclination of the telescope's horizontal rotation axis can affect angular observations, particularly when sighting elevated or depressed targets. The system supports inspection of this axis relationship as part of professional instrument calibration procedures.
The F550CMOS1-D4A incorporates a CMOS digital camera for optical image acquisition. Digital images are transferred to the computer through a USB 3.0 interface for observation and software-assisted measurement.
The digital imaging architecture distinguishes this model from conventional calibration stands equipped with analog CCD cameras and standalone LCD monitors.
A dedicated computer and 24-inch display provide the operating environment for the calibration software.
| Parameter | Specification |
|---|---|
| Model | F550CMOS1-D4A |
| System Type | Computerized Optical Calibration System |
| Installation Type | Floor-Standing |
| Collimator Focal Length | 550 mm |
| Clear Aperture | 55 mm |
| Minimum Reticle Graduation | 15″ |
| Imaging Technology | CMOS Digital Camera |
| Digital Image Resolution | 2592 × 1944 Pixels |
| Pixel Size | 2.2 × 2.2 μm |
| LCD Monitor | 24 inches |
| Display Resolution | 1920 × 1080 |
| Digital Communication Interface | USB 3.0 |
| Processor | Intel Core i5-7400 |
| Memory | 8 GB DDR4-2666 |
| Storage | 256 GB M.2 |
| Measurement Software | Dedicated Calibration Software |
| Weight | Approx. 200 kg |
Surveying instrument calibration systems differ not only in their optical configurations but also in how technicians observe and measure instrument deviations.
| Calibration System | Observation Method | Main Application |
|---|---|---|
| Conventional Optical Collimator | Direct Optical Observation | Routine Optical Inspection |
| CCD Calibration Stand | Electronic Image Monitoring | Optical and Laser Alignment Inspection |
| Computerized CMOS System | Digital Imaging and Measurement Software | Software-Assisted Instrument Error Measurement |
The F550/D3A conventional optical collimator is a practical choice for routine manual instrument calibration.
The F550CMOS1-D4A is intended for facilities that require computer-assisted measurement of instrument errors rather than electronic image observation alone.
The computerized calibration system supports relevant inspection and calibration procedures for:
Electronic and optical total stations
Electronic theodolites
Optical theodolites
Compatible surveying levels
For laboratories servicing total stations and theodolites, the system provides a dedicated platform for evaluating instrument alignment and relevant angular errors.
Specific measurement procedures depend on instrument compatibility, software functions and the applicable calibration requirements.
The F550CMOS1-D4A is particularly relevant to surveying instrument manufacturers, professional calibration laboratories, metrology institutions, equipment quality control departments and advanced instrument repair centers.
When establishing a computerized calibration facility, buyers should consider the required measurement functions, software compatibility, instrument mounting arrangements and operator training requirements.
RTKSurvey.com supplies computerized calibration systems, conventional optical collimators and CCD-assisted calibration stands for international surveying equipment customers.
Explore our complete range of optical collimators and surveying instrument calibration equipment.
Contact us for F550CMOS1-D4A pricing, software configuration, instrument compatibility and international delivery information.